Installation Guide – Eco Luxury Series


Important Notice

  • This product is designed for indoor residential and light commercial use only. Do not installin outdoor areas, pool areas, saunas, open or sun-exposed rooms, or other high-moisture environments.
  • This product must be installed using the floating installation method only.
  • Installation should be carried out by a qualified flooring installer or licensed tradesperson.
  • Environmental conditions during and after installation must be maintained between 15°C –30°C and relative humidity 30% – 75% (ATFA Guidelines).
  • Under Australian Consumer Law (ACL), these installation guidelines form part of thewarranty conditions. Failure to follow these instructions may void the product warranty.


Before Installation

Storage & Acclimatisation:

  • Store cartons flat in a dry, shaded, and well-ventilated area.
  • Allow flooring to acclimatise in the installation environment for at least 48 hours before installation.

Subfloor Requirements:

  • Suitable subfloors: concrete, plywood, OSB, ceramic tiles, or other solid surfaces.
  • Unsuitable subfloors: carpet, carpet underlay, existing floating floors.
  • Flatness: maximum 3mm over 3m (ATFA Guidelines, NCC Tolerances).
  • Moisture content: Timber/wood-based subfloors ≤ 14% (ATFA Standard); Concrete ≤ 2.5% CM Method (ATFA & ASTM F2170).

Moisture Barrier (Mandatory in Queensland):

  • A minimum 200 μm polyethylene moisture barrier must be installed over concrete subfloors (AS 2870 – Residential Slabs and Footings, NCC Volume 2 Part 3.2.2.6).
  • Overlaps must be ≥200mm and seams sealed with moisture-resistant tape.
  • Exemption only applies if written certification confirms the subfloor has an integrated damp-proof membrane.Acoustic Requirements (Apartments & Multi-Storey Buildings):
  • Although the product includes an attached acoustic underlay, additional acoustic underlayment may be required to comply with NCC Volume 1, F5.5 Acoustic Requirements and Body Corporate by-laws (e.g., AAAC 5-star rating).

Heating Systems

Compatible with hydronic underfloor heating systems if installed and operated according to the heating system manufacturer’s guidelines.

Electric underfloor heating is permitted, provided:

  • The surface temperature does not exceed 27°C (ATFA Guidelines), and
  • The heating system is installed with gradual temperature controls.

Rapid heating or cooling cycles must be avoided.

Expansion & Layout

  • Maintain 6–10mm expansion gaps at all walls, door frames, pipes, and fixed objects (ATFA Guidelines).
  • Maximum continuous installation area: 12m length or width. For larger areas, use expansion joints or transition trims (ATFA Standard).
  • Do not install permanent fixtures such as kitchen cabinets or islands directly on top of the floating floor.

Installation Steps

  • Plan the layout so the last row is at least 5cm wide and board end pieces are at least 30cm long (ATFA Standard).
  • Stagger end joints by at least 30cm in adjacent rows.
  • Lock boards together using the tongue-and-groove system at a slight angle, then drop and tap gently into place using a tapping block and rubber mallet.
  • Avoid overuse of force to protect locking mechanisms.

After Installation

  • Clean with a broom or vacuum with soft bristles.
  • Mop with a lightly damp mop and vinyl-appropriate cleaner. Do not use steam mops.
  • Wipe up spills immediately.